HVAC Code Lookup

Goodman Furnace Code E11

Safety fault

Rollout switch is open. A manual-reset safety on the burner assembly tripped because flame rolled out of the heat exchanger instead of being pulled into it.

Manual wording: “Open rollout switch.

Documented for: Goodman GMVC96, GCVC96, GMVM97, GCVM97, GM9S80, GC9S80, GR9S80, GD9S80, GR9T96, GD9T96 (seven-segment display controls)

Likely causes, most common first

  1. Gas pressure too high
  2. Burners mis-aligned
  3. Restricted heat exchanger or venting

What you can safely check yourself

  • Turn the furnace off at its power switch and leave it off
  • If you smell gas, leave the house and call the gas utility from outside

When to call a technician

Flame rollout means combustion gases escaped the burner box. Technician only - never reset a rollout switch yourself.

A Goodman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Goodman codes