Goodman Furnace Code 3
Soft lockoutShown as: 3 flashes, then a pause, repeating
Pressure switch open. The draft inducer is running but the vent pressure switch never closed, so the furnace will not light. Usually a venting or drain blockage.
Manual wording: “Pressure Switch stuck Open”
Documented for: Goodman GMS8, GMH8, GDS8, GDH8, GHS8, GME8, GMES80, GCES80, GMSS92, GMSS96, GCSS96 (single red diagnostic LED)
Likely causes, most common first
- Pressure switch hose blocked, pinched or connected improperly
- Blocked flue or weak induced draft blower
- Blocked inlet air pipe or blocked drain system (condensing models)
- Incorrect pressure switch setpoint or malfunctioning switch contacts
- Loose or improperly connected wiring
What you can safely check yourself
- Go outside and check the intake and exhaust pipes for snow, ice, leaves, a bird nest or other blockage
- On a high-efficiency furnace, check the condensate drain line and trap for a clog or standing water
- Check that the vent terminal is not buried by drifting snow
When to call a technician
If the pipes and drain are clear, the pressure switch, hose and induced draft blower need a technician. Do not jumper or bypass the pressure switch.
A Goodman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.