Goodman Furnace Code 7
WarningShown as: 7 flashes, then a pause, repeating
Low flame sense signal. The furnace is still running normally, but the flame sensor current has dropped low enough that the control is warning you it is about to start failing to light.
Manual wording: “Low Flame Sense Signal”
Documented for: Goodman GMS8, GMH8, GDS8, GDH8, GHS8, GME8, GMES80, GCES80, GMSS92, GMSS96, GCSS96 (single red diagnostic LED)
Likely causes, most common first
- Flame sensor is coated or oxidized
- Flame sensor incorrectly positioned in the burner flame
- Lazy burner flame due to improper gas pressure or combustion air
What you can safely check yourself
- No homeowner action - the furnace is still heating. Schedule service before the code turns into a 1-flash ignition lockout
When to call a technician
Cleaning and repositioning a flame sensor means working inside the burner compartment of a live gas appliance. Book a service call.
A Goodman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.