28 documented codes for Carrier furnaces, each cited to the manufacturer's own manual. Carrier, Bryant and Payne are all ICP/Carrier (Carrier Global) brands and share the same furnace control boards and the same 2-digit LED status-code system. A Bryant 926 or Payne PG92 will flash the same code numbers as the equivalent Carrier 58-series furnace..

Furnace codes

CodeMeaningSeverity
LED offStatus LED is completely dark - no flashing at allThe control board has no powerWarning
LED on solidStatus LED glows steady, no flashingNormalStatus
rapid flashVery fast continuous flashing with no pause between flashesLine voltageHard lockout
10.1Rapid flashing LED; the 3-digit display reads 10.1L1 polarity faultHard lockout
111 short flash, 1 long flashNo previous codeStatus
121 short flash, 2 long flashesBlower on after power upStatus
131 short flash, 3 long flashesLimit circuit lockoutSoft lockout
141 short flash, 4 long flashesIgnition lockoutSoft lockout
14.2Major code 14 flashed on the LED (1 short, 4 long); 14.2 on the 3-digit displayFlame lost lockoutSafety fault
14.3Major code 14 flashed on the LED (1 short, 4 long); 14.3 on the 3-digit displayFlame lost lockoutSafety fault
151 short flash, 5 long flashesBlower motor lockoutSoft lockout
212 short flashes, 1 long flashGas heating lockoutHard lockout
222 short flashes, 2 long flashesAbnormal flame-proving signalSafety fault
232 short flashes, 3 long flashesPressure switch did not openWarning
242 short flashes, 4 long flashesThe 3-amp secondary voltage fuse on the control board is blown, which means there is a short somewhere in the 24 V low-voltage wiringHard lockout
252 short flashes, 5 long flashesModel selection or setup errorWarning
313 short flashes, 1 long flashPressure switch did not close, or reopened during the cycleWarning
323 short flashes, 2 long flashesLow-heat pressure switch did not close on a call for low heat, or opened during low heatWarning
333 short flashes, 3 long flashesLimit circuit faultSoft lockout
343 short flashes, 4 long flashesIgnition proving failureWarning
414 short flashes, 1 long flashBlower motor faultWarning
424 short flashes, 2 long flashesInducer motor faultWarning
434 short flashes, 3 long flashesThe low-heat pressure switch is open while the high-heat pressure switch is closed - a contradictory pressure switch state on a two-stage furnaceWarning
454 short flashes, 5 long flashesControl circuitry lockoutSoft lockout
45.1Major code 45 on the LED (4 short, 5 long); 45.1 on the 3-digit displayControl failure - flame circuit fault, memory mismatch, or sequence error inside the control boardSoft lockout
45.2Major code 45 on the LED (4 short, 5 long); 45.2 on the 3-digit displayControl failure - the gas valve relay on the control board will not closeSafety fault
45.3Major code 45 on the LED (4 short, 5 long); 45.3 on the 3-digit displayControl failure - EEPROM memory issue on the control boardSoft lockout
46.1Major code 46 on the LED (4 short, 6 long); 46.1 on the 3-digit displayMomentary loss of powerStatus