Daikin Mini-Split Code UA
Soft lockout
On pair systems, unspecified voltage between indoor and outdoor unit - a pair-type and a multi-type unit have been connected together. On multi-zone systems the same code means mismatching of indoor and outdoor units or too many indoor units connected.
Manual wording: “UA Unspecified voltage (between indoor unit and outdoor unit)”
Documented for: All Daikin residential ductless; meaning differs between pair and multi-zone platforms
Likely causes, most common first
- Wrong models interconnected
- Wrong wiring of connecting wires
- Wrong indoor unit PCB or outdoor unit PCB mounted
- Defective indoor unit PCB
- Defective outdoor unit PCB
- Excess of connected indoor units (multi-zone)
- Mismatching of the refrigerant type of indoor and outdoor unit (multi-zone)
- Outdoor unit PCB setting not performed after replacing with a spare parts PCB (multi-zone)
What you can safely check yourself
- Turn the system off at the breaker or disconnect switch, wait a minute, and turn it back on once
When to call a technician
UA is essentially an installation or parts-compatibility problem. Whoever installed or last serviced the system needs to verify the indoor/outdoor combination and the wiring.
A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Service Manual - Inverter Pair FTXS-L Series / FDXS-L Series (SiUS091133) (Daikin, FTXS09/12/15/18/24/30/36LVJU wall mount, FDXS09/12LVJU ducted, RKS/RXS09-36LVJU outdoor) · checked 2026-08-25
- Service Manual - Inverter Pair Wall Mounted Type H-Series (SiUS04-924_A) (Daikin, FTXS30/36HVJU indoor, RKS30/36HVJU and RXS30/36HVJU outdoor) · checked 2026-08-25
- Service Manual - Inverter Pair Wall Mounted Type FTXM-W/V Series (SiUS042113EA) (Daikin, FTXM-W / FTXM-V (Daikin Atmosphera) wall-mount heat pump) · checked 2026-08-25
- Service Manual - Multi-Split Type Air Conditioners RMXS-L Series (SiUS181631EA) (Daikin, RMXS48LVJU outdoor, BPMKS048A2U/049A3U branch provider, CTXG/CTXS/FTXS/CDXS/FDXS/FVXS/FFQ indoor units) · checked 2026-08-25