HVAC Code Lookup

Daikin Mini-Split Code U5

Warning

Signal transmission error between the indoor unit and the remote controller. Normal communication with the wired controller did not continue for the specified period.

Manual wording: “U5 Signal transmission error between indoor unit and remote controller

Documented for: Systems with a wired wall remote controller

Likely causes, most common first

  1. Connection of two MAIN remote controllers when using two controllers
  2. Defective indoor unit PCB
  3. Defective remote controller
  4. Signal transmission error caused by noise

What you can safely check yourself

  • Turn the system off at the breaker or disconnect switch, wait a minute, and turn it back on once

When to call a technician

If two wall controllers are installed, one must be set to SUB - that dip switch setting and the controller wiring are a technician's job.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Daikin codes