Soft lockout

High voltage of capacitor in main inverter circuit. The main circuit capacitor's voltage waveform looks like an open-phase power supply.

Manual wording: “P1 High voltage of capacitor in main inverter circuit

Documented for: RMXS multi-split outdoor units

Likely causes, most common first

  1. Defective main circuit capacitor
  2. Improper main circuit wiring
  3. Defective main PCB (A1P)

What you can safely check yourself

  • Check both legs of the outdoor unit breaker are on and there has not been a partial power outage

When to call a technician

The main inverter capacitor stores dangerous voltage even after power is off. Only a technician should open the outdoor electrical box.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.