HVAC Code Lookup

Daikin Mini-Split Code L8

Soft lockout

Inverter current abnormality. Inverter secondary current stayed at or above 19.0 A for 5 seconds, or at or above 16.1 A for 260 seconds - the compressor is overloaded.

Manual wording: “L8 Inverter current abnormality

Documented for: RMXS multi-split outdoor units

Likely causes, most common first

  1. Compressor overload
  2. Compressor coil disconnected
  3. Defective main PCB (A1P)

What you can safely check yourself

  • Check the outdoor unit is clear of debris and has proper airflow
  • Check and replace the indoor unit air filters
  • Turn the system off at the breaker or disconnect switch and back on once

When to call a technician

The manual's path is to inspect the compressor and refrigerant system and often replace the compressor. Technician only.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.