Daikin Mini-Split Code J6

Warning

Outdoor heat exchanger thermistor or related abnormality. The outdoor coil temperature sensor is reading open or shorted.

Manual wording: “J6 Outdoor heat exchanger thermistor or related abnormality

Documented for: RKS/RXS pair outdoor units, FTXM-W/V outdoor units, RMXS multi-split outdoor

Likely causes, most common first

  1. Disconnection of the connector for the thermistor
  2. Defective outdoor heat exchanger thermistor
  3. Defective outdoor unit PCB

What you can safely check yourself

  • Turn the system off at the breaker or disconnect switch and back on once

When to call a technician

The outdoor coil sensor drives defrost and high-pressure protection. A technician needs to check and replace it.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.