HVAC Code Lookup

Daikin Mini-Split Code CJ

Warning

Remote controller thermistor abnormality. The temperature sensor built into the wired wall controller read open or shorted. The system can keep running using the indoor unit's own sensor.

Manual wording: “CJ Remote controller thermistor abnormality

Documented for: Systems using a wired wall remote controller

Likely causes, most common first

  1. Defective room temperature thermistor in the wired remote controller
  2. Defective wired remote controller PCB
  3. External factor such as noise

What you can safely check yourself

  • Turn the system off at the breaker or disconnect switch and back on once and see whether CJ comes back

When to call a technician

If CJ keeps returning the wired controller needs replacing. Note the room temperature it senses will be off until then.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Daikin codes