Bryant Furnace: 2 Flashes
A Bryant furnace LED pattern starting with 2 flashes matches 14 documented codes: 21.1, 22.1, 23.1, 23.2, 23.4, 24.1, 25.1, 25.2, 25.3, 25.4, 25.5, 25.6, 25.7, 27. Watch the full pattern (short vs. long flashes) to tell them apart — all 14 are explained below.
Code 21.1: 24 VAC was sensed on the gas valve when it should not be there
24 VAC was sensed on the gas valve when it should not be there. The control turns off and waits before retrying.
Manual wording: “21.1 24VAC sensed on gas valve when shouldn't be. - Turn off power and wait 5 minutes to retry.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Stuck-closed gas valve relay on the control board
- Miswire or short at the gas valve wire
When to call a technician
This code means the board may not be able to keep the gas valve shut. Turn the furnace off at the service switch and call a technician.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 22.1: False flame
False flame. The control senses flame while the gas valve is de-energized. The inducer runs continuously until the fault clears.
Manual wording: “22.1 FALSE FLAME - Flame is proved while gas valve is de-energized. Inducer will run until fault is cleared.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Stuck open or leaky gas valve
When to call a technician
The furnace is detecting burning gas when the valve should be closed. Shut the furnace off at the service switch and call a technician right away. Do not touch the gas valve.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 23.1: Stuck-closed main pressure switch
Stuck-closed main pressure switch. The control expected the main (low-heat) pressure switch to be open before the inducer started, and it was already closed.
Manual wording: “23 1 Stuck closed Main pressure switch”
Documented for: 912SE, 926TC
Likely causes, most common first
- Obstructed pressure tube
- Pressure switch stuck closed
When to call a technician
The pressure switch is a combustion safety device. A technician has to inspect the tube and switch. Never jumper or bypass a pressure switch.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
Code 23.2: Stuck-closed secondary
Stuck-closed secondary (high-heat) pressure switch. On the 926TC label this is listed as the HPS pressure switch.
Manual wording: “23 2 Stuck closed secondary pressure switch”
Documented for: 912SE, 926TC
Likely causes, most common first
- Obstructed pressure tube
- Pressure switch stuck closed
When to call a technician
Pressure switch faults must be diagnosed by a technician. Do not bypass the switch to get heat.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
Code 23.4: Low-heat
Low-heat (LPS) pressure switch fault - the switch did not open when expected.
Manual wording: “23.4 LPS pressure switch”
Documented for: 926TC
Likely causes, most common first
- Obstructed pressure tube
- Pressure switch stuck closed
When to call a technician
Have a technician inspect the pressure tubing and switch; never jumper a pressure switch.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
Code 24.1: Fuse fault - the 24 V secondary voltage fuse on the control board is open, which means there is a short in the low-voltage wiring
Fuse fault - the 24 V secondary voltage fuse on the control board is open, which means there is a short in the low-voltage wiring.
Manual wording: “24.1 FUSE FAULT”
Documented for: 926TC, 912SE
Likely causes, most common first
- Short circuit in the secondary voltage (24 V) wiring, including the thermostat leads
When to call a technician
Simply replacing the fuse blows it again. A technician needs to isolate the shorted thermostat or accessory wire first.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 25.1: No program information in the control's microprocessor - the furnace will not heat
No program information in the control's microprocessor - the furnace will not heat.
Manual wording: “25.1 NO PROGRAM info in micro, no heating operation.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Control board was never programmed, or the program was lost
When to call a technician
The control has to be reprogrammed with the correct program number from the rating plate using the Bryant service app or a super plug. That is dealer-only work.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 25.2: Corrupted program file
Corrupted program file. The control must be reprogrammed with the service app or a super plug; there is no heating operation until it is.
Manual wording: “25.2 CORRUPTED PROGRAM FILE, reprogram control using service app or super plug (supplied separately), no heating operation.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Corrupted program in the control board
When to call a technician
Reprogramming the control requires the dealer's service app or a super plug. Call your Bryant dealer.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 25.3: Twinned units are not identical - the two furnaces' program numbers do not match, so the main unit will not operate
Twinned units are not identical - the two furnaces' program numbers do not match, so the main unit will not operate.
Manual wording: “25.3 TWINNED UNITS ARE NOT IDENTICAL, program #'s do not match. Ensure furnaces are identical (same program #) when twinning. Main unit will not operate.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Two twinned furnaces programmed with different program numbers
When to call a technician
Twinned furnaces have to be reprogrammed to matching program numbers by the installing dealer.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 25.4: Main program invalid - the control is running on its backup program
Main program invalid - the control is running on its backup program. The furnace still operates normally, but the control should be reprogrammed.
Manual wording: “25.4 MAIN PROGRAM INVALID , using backup program to operate. Reprogram control to correct issue. Control still operates normally.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Main program in the control became invalid
What you can safely check yourself
- Nothing urgent - the furnace still runs, but mention this code the next time a technician visits
When to call a technician
Have the dealer reprogram the control at the next service visit.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 25.5: Installer settings corrupted
Installer settings corrupted. The control keeps running on default installer settings until the settings are reselected or the control is reprogrammed.
Manual wording: “25.5 INSTALLER SETTINGS CORRUPTED. Try reselecting installer settings, or reprogram control. Control will operate using default installer settings.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Stored installer settings became corrupted
What you can safely check yourself
- The furnace still runs on defaults - note the code for your technician
When to call a technician
The installer's airflow and delay settings need to be reselected by a dealer so the furnace matches your ductwork again.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 25.6: Wrong program for the control being used - there is no heating operation until the control is reprogrammed to match
Wrong program for the control being used - there is no heating operation until the control is reprogrammed to match.
Manual wording: “25.6 WRONG PROGRAM for control used - reprogram control so program matches control used. No heating operation.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Control programmed with a program that does not match the board installed
When to call a technician
The dealer needs to reprogram the control so the program matches the board and the furnace's rating plate.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 25.7: A non-condensing program was detected in a condensing model furnace
A non-condensing program was detected in a condensing model furnace.
Manual wording: “25.7 NON-CONDENSING PROGRAM detected in a condensing model.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Wrong program loaded into the control after a board replacement
When to call a technician
The control needs the correct program number from the rating plate loaded by a dealer.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 27: The program in the super plug is missing, not recognized, or corrupted
The program in the super plug is missing, not recognized, or corrupted.
Manual wording: “27.1 27.2 27.3 Program in super plug is missing, not recognized, or corrupted. Remove super plug then retry.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Super plug missing, unreadable, or corrupted
When to call a technician
The technician needs to remove the super plug and retry, then try a different super plug; if the code persists the control is replaced.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25