HVAC Code Lookup

Bryant Furnace Code 10.1

Hard lockoutShown as: Rapid, continuous flashing with no pause; display reads 10.1

L1 polarity fault. The polarity of the incoming 115 V power is reversed, so the control cannot prove flame and the furnace will not run.

Manual wording: “10.1 L1 POLARITY FAULT Rapid flash LED

Documented for: 926TC, 912SE

Likely causes, most common first

  1. Line voltage hot and neutral reversed at a junction box, outlet or the furnace
  2. On twinned furnaces, incorrect low-voltage (24 V) transformer phasing

When to call a technician

Correcting reversed 115 V polarity means working inside live junction boxes. Call a licensed HVAC technician or electrician.

A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Bryant codes