HVAC Code Lookup

Bryant Furnace Code 22.1

Safety faultShown as: 2 short flashes, 2 long flashes

False flame. The control senses flame while the gas valve is de-energized. The inducer runs continuously until the fault clears.

Manual wording: “22.1 FALSE FLAME - Flame is proved while gas valve is de-energized. Inducer will run until fault is cleared.

Documented for: 926TC, 912SE

Likely causes, most common first

  1. Stuck open or leaky gas valve

When to call a technician

The furnace is detecting burning gas when the valve should be closed. Shut the furnace off at the service switch and call a technician right away. Do not touch the gas valve.

A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Bryant codes