Bryant Furnace Code 13.1

Soft lockoutShown as: 1 short flash, 3 long flashes

Limit circuit lockout. The limit, draft safeguard, flame rollout, or blocked-vent switch has been open longer than 3 minutes. The control locks out and auto-resets after 3 hours.

Manual wording: “13.1 LIMIT CIRCUIT LOCKOUT - Lockout occurs if the limit, draft safeguard, flame rollout, or blocked vent switch*(if used) is open longer than 3 minutes. Control will auto-reset after 3 hours. See code 33.

Documented for: 926TC, 912SE

Likely causes, most common first

  1. Sustained overheating from restricted airflow - see code 33 for the full cause list
  2. Flame rollout switch tripped (requires manual reset by a technician)
  3. Defective limit switch or connections

What you can safely check yourself

  • Check and replace a dirty air filter
  • Make sure supply registers and return grilles are open and not blocked
  • Make sure the furnace blower door is fully closed and latched

When to call a technician

A 3-minute limit trip means the furnace was genuinely overheating or not venting. Have a technician confirm why before running it again - a tripped flame rollout switch in particular must never be reset without finding the cause.

A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.