HVAC Code Lookup

Bryant Furnace Code 32.1

WarningShown as: 3 short flashes, 2 long flashes

Open main pressure switch (LPS) - the main low-heat pressure switch is open when it should be closed.

Manual wording: “32 1 Open Main pressure switch (LPS)

Documented for: 912SE

Likely causes, most common first

  1. Restricted vent or blocked intake/exhaust termination
  2. Plugged condensate drain
  3. Disconnected or obstructed pressure tubing
  4. Defective inducer motor
  5. Defective pressure switch
  6. Excessive wind

What you can safely check yourself

  • Check outdoor intake and exhaust pipes for snow, ice, leaves, or a nest
  • Check the condensate drain line and trap for a clog
  • Replace a dirty filter

When to call a technician

If venting and drain are clear, the inducer or pressure switch needs testing by a technician.

A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.