HVAC Code Lookup

Bryant Furnace Code 31.3

Soft lockoutShown as: Major code 31 on the LED (3 short, 1 long); 31.3 on the display

Secondary pressure switch lockout - the secondary (high-heat) pressure switch failed to close after three trials.

Manual wording: “31 3 Secondary PS Lockout - failed to close secondary PS after three trials

Documented for: 912SE

Likely causes, most common first

  1. Restricted or improperly sized vent
  2. Plugged condensate drain
  3. Obstructed or disconnected pressure tubing
  4. Failed inducer motor or pressure switch

What you can safely check yourself

  • Check outdoor vent terminations for snow, ice or debris
  • Check the condensate drain and trap for a clog

When to call a technician

Three failed attempts to make the pressure switch means the venting or the inducer needs a technician's inspection.

A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Bryant codes