Bryant Furnace Code 31.2
WarningShown as: 3 short flashes, 1 long flash; 31.2 on the display
Open secondary pressure switch (HPS) - the high-heat pressure switch did not close, or reopened, when the control needed it.
Manual wording: “31 2 Open secondary pressure switch (HPS)”
Documented for: 912SE
Likely causes, most common first
- Restricted vent or blocked intake/exhaust termination
- Plugged condensate drain
- Excessive wind at the vent
- Disconnected or obstructed pressure tubing
- Defective inducer motor or low inducer voltage
- Defective pressure switch
What you can safely check yourself
- Go outside and check the furnace intake and exhaust pipes for snow, ice, leaves, or a nest and clear any blockage
- Check the condensate drain line and trap for a clog
- Replace a dirty air filter
When to call a technician
If the vents are clear and the drain is open, the inducer, pressure switch, or tubing needs a technician. Never jumper a pressure switch.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25