Bryant Furnace: 4 Flashes
A Bryant furnace LED pattern starting with 4 flashes matches 5 documented codes: 41, 45.1, 45.2, 45.3, 46.1. Watch the full pattern (short vs. long flashes) to tell them apart — all 5 are explained below.
Code 41: No blower RPM
No blower RPM. 41.1 means no blower RPM at start-up; 41.2 means no blower RPM after the motor was already running.
Manual wording: “41.1 NO BLOWER RPM - No blower rpm at startup 41.2 NO BLOWER RPM - No blower rpm when blower motor is running.”
Documented for: 926TC
Likely causes, most common first
- Loose blower wire connections
- Failed blower motor
What you can safely check yourself
- Make sure the blower access door is fully closed and latched
- Turn the furnace off at the service switch for a minute and back on once
When to call a technician
An ECM blower motor and its wiring have to be tested by a technician.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
Code 45.1: Control failure - flame circuit fault, memory mismatch, or sequence error on the control board
Control failure - flame circuit fault, memory mismatch, or sequence error on the control board.
Manual wording: “45.1 CONTROL FAILURE - flame circuit fault, memory mismatch or sequence error.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Internal control board failure
What you can safely check yourself
- Turn the furnace off at the service switch for a minute and back on once - the label says to cycle power
When to call a technician
Bryant's own instruction is that if code 45 repeats after cycling power, the control must be replaced.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 45.2: Control failure - the gas valve relay will not close
Control failure - the gas valve relay will not close.
Manual wording: “45.2 CONTROL FAILURE - gas valve relay will not close.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Failed gas valve relay on the control board
What you can safely check yourself
- Turn the furnace off at the service switch and leave it off until a technician arrives
When to call a technician
A gas valve relay that will not close means the board cannot reliably shut off gas. Shut the furnace down and call a technician; the fix is a new control.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 45.3: Control failure - EEPROM memory issue on the control board
Control failure - EEPROM memory issue on the control board.
Manual wording: “45.3 CONTROL FAILURE - EEPROM memory issue.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Corrupted or failed memory on the control board
What you can safely check yourself
- Turn the furnace off at the service switch for a minute and back on once
When to call a technician
If the code repeats after a power cycle, the control board has to be replaced by a technician.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25
Code 46.1: Momentary loss of power
Momentary loss of power. Heating stops and restarts on its own once the power fluctuation is resolved.
Manual wording: “46.1 MOMENTARY LOSS of power - Heating operation will stop and will restart once the power fluctuation is resolved.”
Documented for: 926TC, 912SE
Likely causes, most common first
- Brownout or brief power interruption to the furnace
What you can safely check yourself
- Nothing to fix if you had a power blip
- If it repeats without outages, check that the breaker is fully on and the furnace switch is not loose
When to call a technician
Frequent 46.1 codes with no utility outages usually mean a loose 115 V connection or failing door switch - have a technician look.
A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-up, Operating and Service and Maintenance Instructions - 926TC (Bryant Heating & Cooling Systems, 926TC Preferred Series two-stage, variable-speed ECM multipoise condensing gas furnace) · checked 2026-08-25
- Installation, Start-up, Operating and Service and Maintenance Instructions - 912SE (Bryant Heating & Cooling Systems, 912SE Legacy Line 92% single-stage condensing gas furnace) · checked 2026-08-25