Payne Furnace Code 43
WarningShown as: 4 short flashes, 3 long flashes
Low-heat pressure switch open while the high-heat pressure switch is closed - a contradictory pressure-switch state on a two-stage furnace.
Manual wording: “43 LOW-HEAT PRESSURE SWITCH OPEN WHILE HIGH-HEAT PRESSURE SWITCH IS CLOSED”
Documented for: PG96VTA
Likely causes, most common first
- Low-heat pressure switch stuck open
- Disconnected or obstructed pressure tube
- Miswired pressure switches
- Low inlet gas pressure (if LGPS used)
- Plugged condensate drain
- Water in the vent piping from a sagging pipe
What you can safely check yourself
- Check the condensate drain line and trap for a clog or standing water
- Check outdoor vent terminations for blockage
When to call a technician
Pressure switch wiring and vent piping slope are technician diagnostics. Never jumper a pressure switch.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- PG96VTA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG96VTA two-stage, variable-speed ECM 4-way multipoise condensing gas furnace) · checked 2026-08-25