HVAC Code Lookup

Payne Furnace Code 42

WarningShown as: 4 short flashes, 2 long flashes; minor codes 42.1, 42.2 and 42.3

Inducer RPM fault. 42.1 means no RPM feedback at start-up or before ignition proved; 42.2 means the RPM signal was lost for 5 seconds after ignition proved; 42.3 means the inducer is exceeding its model-specific RPM limit.

Manual wording: “42.1 NO RPM FEEDBACK - at start-up or before ignition proved. 42.2 NO RPM FEEDBACK - after ignition proved, signal was lost for 5 seconds. 42.3 EXCEEDING INDUCER RPM LIMIT

Documented for: PG80MSU

Likely causes, most common first

  1. Improper vent sizing
  2. Restricted combustion air supply
  3. Failed inducer motor
  4. Improper or loose motor wiring or a bad connection

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice, leaves, or a nest blocking them

When to call a technician

The inducer motor and its wiring must be tested by a technician. A furnace that cannot run its inducer cannot vent combustion gases safely.

A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Payne codes