HVAC Code Lookup

Payne Furnace Code 23

WarningShown as: 2 short flashes, 3 long flashes

Pressure switch did not open. The control expected the pressure switch to be open before the inducer started and it was already closed.

Manual wording: “23 PRESSURE SWITCH DID NOT OPEN - Check for: - Obstructed pressure tube. - Pressure switch stuck closed.

Documented for: PG92ESA, PG95ESA, PG96VTA

Likely causes, most common first

  1. Obstructed pressure tube
  2. Pressure switch stuck closed

When to call a technician

The pressure switch is a combustion safety device. A technician must inspect the tubing and switch. Never jumper or bypass a pressure switch.

A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Payne codes