HVAC Code Lookup

Payne Furnace Code 14.3

Safety faultShown as: Major code 14 flashed on the LED (1 short, 4 long); 14.3 on the display

Flame lost lockout - the flame signal was lost seven times during a single heat request.

Manual wording: “14.3 FLAME LOST LOCKOUT - Flame signal was lost 7 times during a single heat request. See status code 34.2 to 34.4.

Documented for: PG80MSU

Likely causes, most common first

  1. Incorrect manifold pressure and gas firing rate
  2. Gas inlet pressure fluctuations
  3. Improper pressure transducer operation

What you can safely check yourself

  • Check that the air filter is clean and supply and return vents are open

When to call a technician

Do not keep resetting the furnace. Seven flame losses in one heat call needs a technician to check gas supply and the combustion setup.

A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Payne codes