Mitsubishi Electric Mini-Split Code U4

Soft lockout

Open or short circuit of one of the outdoor unit thermistors (TH3 liquid, TH32 suction, TH6 two-phase pipe, TH7 ambient, TH8 heatsink), detected during compressor operation.

Manual wording: “Open/short of outdoor unit thermistors (TH3, TH32, TH6, TH7, and TH8) - Abnormal if open or short is detected during compressor operation.

Documented for: A-Control outdoor units (PUZ, MUZ, MXZ)

Likely causes, most common first

  1. Disconnection or contact failure of the thermistor connectors on the outdoor controller circuit board or connector CN6 on the outdoor power circuit board
  2. Defective thermistor
  3. Defective outdoor controller circuit board

What you can safely check yourself

  • Turn the system off at the breaker, wait one minute, and turn it back on once

When to call a technician

Identifying which of the five outdoor sensors failed requires the service tool and resistance measurements inside the outdoor unit. Call a technician.

A Mitsubishi Electric mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.