HVAC Code Lookup

Mitsubishi Electric Mini-Split 5 Blinks

Soft lockoutShown as: Upper OPERATION INDICATOR lamp blinks 5 times, then 2.5 seconds off, repeating

Outdoor power system error. The compressor shut down on overcurrent protection or startup-failure protection three times in a row within one minute of starting. Neither the indoor nor the outdoor unit will run.

Manual wording: “Outdoor power system - It consecutively occurs 3 times that the compressor stops for overcurrent protection or startup failure protection within 1 minute after startup.

Documented for: MSZ-GL and MSY-GL indoor units paired with MUZ-GL, MUY-GL or MXZ outdoor units

Likely causes, most common first

  1. Outdoor unit service (stop) valve closed or not fully open
  2. Compressor connecting wire loose, disconnected or reversed
  3. Defective compressor or inverter P.C. board
  4. Low supply voltage

What you can safely check yourself

  • Check that the outdoor unit is clear of snow, ice, leaves and debris and has open air space around it
  • Check that the breaker feeding the outdoor unit is on and not tripped
  • Turn the system off at the breaker, wait one minute, and turn it back on once

When to call a technician

Stop valves, compressor wiring and inverter boards are all inside the outdoor unit under high voltage and refrigerant pressure. This one needs a technician.

A Mitsubishi Electric mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.