HVAC Code Lookup

Mitsubishi Electric Mini-Split Code U2

Soft lockout

Abnormal high discharge temperature or high compressor surface temperature, which usually means the system is short of refrigerant. The discharge thermistor TH4 exceeded 230F for 5 minutes, or the compressor surface thermistor TH33 exceeded 257F.

Manual wording: “Abnormal high discharge temperature, shortage of refrigerant ... Abnormal if TH4 exceeds 230F [110C] or more continuously for 30 seconds

Documented for: A-Control outdoor units (PUZ, MUZ, MXZ)

Likely causes, most common first

  1. Shortage of refrigerant
  2. Defective operation of the stop valve (not fully open)
  3. Defective action of the linear expansion valve
  4. Clogging with foreign objects in the refrigerant circuit
  5. Defective discharge or compressor-surface thermistor
  6. Defective outdoor controller board

What you can safely check yourself

  • Check the outdoor unit is clear of snow, ice and debris
  • Turn the system off at the breaker, wait one minute, and turn it back on once

When to call a technician

This code points at a refrigerant charge or expansion valve problem. Refrigerant work requires EPA certification and gauges. Call a technician.

A Mitsubishi Electric mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Mitsubishi Electric codes