HVAC Code Lookup

Mitsubishi Electric Mini-Split Code F3

Soft lockout

The 63L low pressure switch connector (red) on the outdoor controller board is open. Detected when power is turned on.

Manual wording: “F3 63L connector(red) is open.

Documented for: PUZ-HA and other A-Control outdoor units fitted with a low pressure switch

Likely causes, most common first

  1. 63L connector disconnected or has contact failure on the outdoor controller board
  2. 63L low pressure switch itself has failed or is tripped
  3. Defective outdoor controller circuit board

What you can safely check yourself

  • Turn the system off at the breaker, wait one minute, and turn it back on once

When to call a technician

63L is a refrigerant pressure safety switch. Never jumper or bypass it - a technician must find out why it is open.

A Mitsubishi Electric mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Mitsubishi Electric codes