Mitsubishi Electric Mini-Split Code E9

Soft lockout

Indoor/outdoor unit communication error - transmitting error detected by the outdoor unit. The outdoor controller board could not find a free slot on the transmission path for 3 minutes.

Manual wording: “E9 Indoor/outdoor unit communication error - Transmitting error (Indoor unit)

Documented for: A-Control outdoor units (PUZ, MUZ, MXZ)

Likely causes, most common first

  1. Indoor/outdoor unit connecting wire has contact failure or is miswired
  2. Defective communication circuit of the outdoor controller board
  3. Defective communication circuit of the indoor controller board
  4. Noise has entered the power supply or the indoor/outdoor connecting wire

What you can safely check yourself

  • Check that the breaker feeding the outdoor unit is on and has not tripped
  • Turn the system off at the breaker, wait one minute, and turn it back on once

When to call a technician

Connecting-wire and board work is a technician job.

A Mitsubishi Electric mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.