HVAC Code Lookup

LG Mini-Split Code CH72

Soft lockoutShown as: Outdoor LED1 blinks 7 times, LED2 blinks 2 times (2-LED type)

Four-way (reversing) valve switching failure. The valve that flips the system between heating and cooling did not change over when commanded, so the unit cannot switch modes.

Manual wording: “Switching for 4 way valve is failed

Documented for: LG single-zone room air conditioner / mini-split heat pump outdoor units

Likely causes, most common first

  1. Indoor or outdoor pipe sensor short or open
  2. Disconnection of the 4-way valve connector
  3. 4-way valve coil open or short
  4. Burned part inside the PCB (4-way valve output)

What you can safely check yourself

  • Turn the system off at the breaker for three minutes and back on, then try the mode change again

When to call a technician

The reversing valve and its coil are on the refrigerant circuit inside the outdoor unit. A technician has to measure the coil resistance and the board's output before deciding what to replace.

A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other LG codes