LG Mini-Split Code CH62
Soft lockoutShown as: Outdoor LED01 (red) blinks 6 times, LED02 (green) blinks 2 times
Outdoor unit inverter compressor PCB heat sink temperature is too high. The aluminium heat sink that cools the inverter power module is overheating, usually because the outdoor unit is in a hot, cramped spot or its airflow is blocked.
Manual wording: “Outdoor unit inverter compressor PCB heat sink temperature is too high”
Documented for: All LG residential mini-split outdoor units
Likely causes, most common first
- Improper installation environment (outdoor unit in a tight, unventilated location)
- Overload operation - outdoor fan restricted, screened, or blocked
- Poor PCB heat sink assembly (heat sink not making good contact)
- Poor PCB temperature sensing circuit parts
What you can safely check yourself
- Clear leaves, grass clippings, snow, or debris away from the outdoor coil and fan
- Remove anything stacked against or on top of the outdoor unit and give it clear space on all sides
- Check nothing is blowing hot exhaust (dryer vent, another condenser) into the outdoor unit
- Let the unit cool, then turn it off at the breaker for three minutes and back on
When to call a technician
If the outdoor unit has clear airflow and CH62 returns, the heat sink mounting or its sensor is at fault and needs a technician. If the unit is genuinely in too tight a space, it may need relocating.
A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- MULTI F / MULTI F MAX Outdoor Unit Installation Manual (LG Electronics U.S.A., Inc., Multi F and Multi F MAX multi-zone heat pump outdoor units (LMU series) with standard wall-mount, Art Cool, cassette and ducted indoor units) · checked 2026-08-25
- Single Zone Four-Way Ceiling-Cassette Installation Manual (LG Electronics U.S.A., Inc., Single-zone four-way ceiling cassette indoor units with LUU090HV through LUU420HV outdoor units) · checked 2026-08-25
- Convertible Mid-Static Ducted LGRED Degree System Installation Manual (LG Electronics U.S.A., Inc., LGRED single-zone convertible mid-static ducted indoor units with LUU180HHV / LUU240HHV outdoor units) · checked 2026-08-25
- Defining Common Error Codes - Standard Wall-Mounted High-Efficiency Single Zone Systems (LG Electronics U.S.A. - Commercial Air Conditioning, LS091HSV and LS121HSV systems (LSN091HSV / LSN121HSV indoor units, LSU091HSV / LSU121HSV outdoor units)) · checked 2026-08-25
- Room Air Conditioner SVC Manual (General) - Trouble Shooting Guide with Error Code (LG Electronics, All LG single-zone room air conditioner / mini-split chassis (SW, SB, SC, S4, S5, SH, SA, SJ, SK)) · checked 2026-08-25