HVAC Code Lookup

LG Mini-Split Code CH42

Soft lockoutShown as: Outdoor LED1 blinks 4 times, LED2 blinks 2 times (2-LED type)

Low pressure sensor open or short. The suction-side pressure transducer is not reporting a valid signal.

Manual wording: “Low pressure Sensor open/short

Documented for: LG single-zone room air conditioner / mini-split outdoor units fitted with pressure sensors

Likely causes, most common first

  1. Bad wiring of the pressure sensor
  2. Bad pressure sensor

What you can safely check yourself

  • Turn the system off at the breaker for three minutes and back on

When to call a technician

Pressure transducers are mounted on the refrigerant circuit. Replacement is technician work.

A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other LG codes