HVAC Code Lookup

LG Mini-Split Code CH32

Soft lockoutShown as: Outdoor LED01 (red) blinks 3 times, LED02 (green) blinks 2 times

Inverter compressor discharge pipe (D-pipe) temperature is too high. The gas leaving the compressor is overheating, which most often means the outdoor unit cannot reject heat or the system is low on refrigerant.

Manual wording: “Inverter compressor discharge pipe (D-Pipe) temperature is too high

Documented for: All LG residential mini-split outdoor units

Likely causes, most common first

  1. Overload operation - outdoor fan restricted, screened, or blocked
  2. Poor inverter compressor discharge sensor
  3. Refrigerant leakage (insufficient charge)
  4. EEV connector displaced or poor EEV (electronic expansion valve) assembly

What you can safely check yourself

  • Clear leaves, grass clippings, snow, or debris away from the outdoor coil and fan
  • Remove anything stacked against or on top of the outdoor unit
  • Check and clean the indoor air filters
  • Give the unit time to cool down, then turn it off at the breaker for three minutes and back on

When to call a technician

If airflow is clear and CH32 returns, the system is likely low on refrigerant or the expansion valve is misbehaving. Both require a licensed technician with gauges.

A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other LG codes