HVAC Code Lookup

LG Mini-Split Code CH24

Hard lockoutShown as: Outdoor LED1 blinks 2 times, LED2 blinks 4 times

Pressure switch / heat sink protection has tripped. The outdoor unit's protective switch opened, which normally means the system cannot reject heat - blocked coil, blocked airflow, or a refrigerant-side problem.

Manual wording: “24 Pressure Switch / Heater Sink.

Documented for: LUU090HV ~ LUU420HV and LUU180HHV / LUU240HHV single-zone outdoor units

What you can safely check yourself

  • Clear leaves, grass clippings, snow, or debris away from the outdoor coil and fan
  • Remove anything stacked against or on top of the outdoor unit
  • Check and clean the indoor air filters
  • Make sure the indoor supply and return grilles are open

When to call a technician

A tripped pressure switch is a protection device doing its job. Never bypass, jumper, or reset a pressure switch - a technician has to find why it tripped.

A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.