HVAC Code Lookup

Lennox Furnace Code E312

Warning

Restricted air flow in cooling or continuous fan mode. The blower is delivering less air than its cfm setting because the variable speed motor has hit its built-in speed and torque limits.

Manual wording: “Restricted air flow in cooling or continuous fan mode is lower than cfm setting. Indoor blower is running at a reduced cubic feet per minute (Cutback Mode).

Documented for: SLP98UHV series

Likely causes, most common first

  1. Dirty air filter
  2. Restricted or undersized ductwork pushing total external static pressure above 0.8 inches water column
  3. Closed or blocked registers

What you can safely check yourself

  • Check the air filter and replace it if it is dirty
  • Make sure supply and return registers throughout the house are open and unblocked
  • Check that the return grille is not covered

When to call a technician

The manual's action is to replace the filter if needed or repair and add ductwork. If a clean filter does not clear it, static pressure has to be measured by a technician.

A Lennox furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.