Lennox Furnace Code 3
WarningShown as: 3 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats
The burners failed to light during a heat call, or a flame that was lit went out before the heat demand was satisfied.
Manual wording: “3 - Burner failed to light, or lost flame during heat demand”
Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01
Likely causes, most common first
- No gas supply to the furnace, or the manual gas valve is closed
- Dirty or failed flame sensor so the control cannot prove the flame
- Failed or cracked hot surface ignitor
- Condensate or vent restriction interrupting the burner cycle
What you can safely check yourself
- Check that other gas appliances in the house (range, water heater) are working, which tells you whether gas is being delivered
- Check that the furnace door is fully seated, since the door switch must be closed for the furnace to fire
- Check the outdoor intake and exhaust pipes for snow, ice, leaves or nesting debris
- Turn the furnace power switch off for 30 seconds and back on once
When to call a technician
If the code returns, the ignitor, flame sensor, gas valve or gas pressure needs to be tested. Do not open the burner compartment or touch the gas valve yourself.
A Lennox furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.