Lennox Furnace Code E271
Soft lockout
Soft lockout. The furnace used up its ignition retries and the last attempt failed because the pressure switch opened.
Manual wording: “Soft lockout - Exceeded maximum number of retries. Last retry failed due to the pressure switch opening.”
Documented for: EL296UHE and SLP98UHV series
Likely causes, most common first
- Blocked or restricted intake or exhaust vent pipe
- Plugged condensate drain or trap
- Loose or wet pressure switch tubing
- Failing combustion air inducer
What you can safely check yourself
- Check the outdoor intake and exhaust pipes for snow, ice or debris
- Check the condensate drain line and trap for a clog
- Turn the furnace power switch off for 30 seconds and back on once, one time only
When to call a technician
Same diagnosis as E223: the manual calls for measuring pressure switch closing pressure and inspecting the vent and inducer for restriction. Have a technician do it.
A Lennox furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.