HVAC Code Lookup

Fujitsu Mini-Split Code 82

Soft lockoutShown as: OPERATION lamp blinks 8 times, TIMER lamp blinks 2 times, ECONOMY lamp blinking continuously

Sub-cool heat exchanger gas inlet or gas outlet thermistor error. One of the sub-cooling heat exchanger gas sensors is shorted or open.

Manual wording: “Sub-Cool Heat Ex. Gas Inlet Thermistor Error / Sub Cool Heat Ex. Gas Outlet Thermistor Error - Sub cooling heat exchanger gas inlet temperature thermistor short or open detected.

Documented for: RLF/RLF1 multi-zone systems on larger RLXFZ outdoor units

Likely causes, most common first

  1. Erroneous connection or removed connector
  2. Thermistor resistance out of specification
  3. Failed outdoor main PCB

What you can safely check yourself

  • Turn the power off at the outdoor disconnect and breaker for about 5 minutes, then restore power

When to call a technician

Sub-cool circuit sensors are deep inside the outdoor unit. A technician must diagnose this.

A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Fujitsu codes