HVAC Code Lookup

Fujitsu Mini-Split Code 73

Soft lockoutShown as: OPERATION lamp blinks 7 times, TIMER lamp blinks 3 times, ECONOMY lamp blinking continuously

Heat exchanger (pipe) thermistor error at the outdoor unit. The outdoor coil pipe sensor is open or short-circuited.

Manual wording: “Heat Exchanger (Pipe) Thermistor Error - When heat exchanger temperature thermistor open or short-circuit is detected at power up or while running the compressor.

Documented for: RGLX, RL2/RLS3/RLB/RLXB, RLF/RLF1 outdoor units. On 30RLXEH this position also covers heat exchanger middle temperature and heat exchanger liquid temperature thermistor errors

Likely causes, most common first

  1. Loose or erroneous connector connection
  2. Open or shorted outdoor pipe thermistor
  3. Failed outdoor main PCB

What you can safely check yourself

  • Turn the power off at the outdoor disconnect and breaker for about 5 minutes, then restore power

When to call a technician

Replacing the outdoor coil sensor means working inside the condenser cabinet. Call a technician.

A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.