Fujitsu Mini-Split Code 58
WarningShown as: OPERATION lamp blinks 5 times, TIMER lamp blinks 8 times, ECONOMY lamp blinking continuously
Intake grille error. The micro switch that proves the intake grille is closed read open while the compressor was running.
Manual wording: “Intake Grille Error - When the micro switch is detected open while running the compressor.”
Documented for: RLF multi-zone and RLS3/RLB/RLXB wall mounted indoor units with a powered intake grille
Likely causes, most common first
- Intake grille or front panel not fully closed and latched
- Failed limit / micro switch
- Loose connector CN11 or damaged wire
- Failed indoor controller PCB
What you can safely check yourself
- Open and re-close the intake grille or front panel until it clicks fully shut on both sides
- Make sure the filters are seated properly so the grille can close all the way
- Turn the power off at the breaker for about 5 minutes and back on
When to call a technician
If the grille is definitely latched and the code stays, the micro switch or its wiring has failed and a technician must replace it.
A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- 410A Mini-Split Troubleshooting Guide (Part # 6-26-FG2020 Rev. 5/2019) (Fujitsu General America, Inc., All R410A Halcyon mini-splits: RGLX, RL2/RLS3/RLS3H/RLS3Y/RLB/RLXB/RLXEH wall mounted, RLF/RLF1 multi-zone indoor units, RLXFZ multi-zone outdoor units, RML/RMLQ, RULX/RSLX universal-mount, RCLX cassettes) · checked 2026-08-25