HVAC Code Lookup

Fujitsu Mini-Split Code 33

Soft lockoutShown as: OPERATION lamp blinks 3 times, TIMER lamp blinks 3 times, ECONOMY lamp blinking continuously

Indoor unit motor electricity consumption detection error. The voltage or current the indoor fan motor is drawing has gone outside its allowed limits.

Manual wording: “Indoor unit motor electricity consumption detection error - When the voltage value or current value of the motor go beyond the limits.

Documented for: AUU18-48RGLX, ARU12-48RGLX

Likely causes, most common first

  1. Indoor fan caught, dropped off its shaft, or the motor is locked
  2. Excessively high ambient temperature around the fan motor from nearby equipment
  3. Failed indoor fan motor
  4. Failed indoor controller PCB

What you can safely check yourself

  • Replace or clean the return air filter
  • Make sure supply and return grilles are open and not blocked by furniture or drapes
  • Turn the power off at the breaker for about 5 minutes and back on

When to call a technician

Checking the blower wheel and motor windings means removing panels with the unit powered. Have a technician do it.

A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Fujitsu codes