Coleman Furnace 9 Red Flashes (CP9C Echelon Modulating)

Hard lockoutShown as: Nine red flashes, two-second pause, repeating

Reversed line polarity or improper grounding at the furnace.

Manual wording: “Nine Red Flashes - Reversed line polarity or improper grounding. Check polarity of the incoming power to the furnace. Check the grounding of the furnace, including the transformer ground and the L1 and neutral connections.

Documented for: CP9C Echelon modulating furnaces

Likely causes, most common first

  1. Line voltage hot and neutral reversed
  2. Poor or missing furnace ground
  3. Bad transformer ground or L1/neutral connection

What you can safely check yourself

  • If this appeared right after electrical work, mention that to the technician
  • Check the furnace breaker is fully on

When to call a technician

Polarity and grounding are line-voltage electrical work. Have a technician or electrician correct it.

A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.