Coleman Furnace Continuous Red Flash

WarningShown as: Red LED flashing on and off continuously with no pauses

Twinning error on the TM9T / TM8T boards: incorrect 24V phasing between two twinned furnaces, or no power to the twinned unit.

Manual wording: “CONTINUOUS RED FLASH: Twinning error, incorrect 24V phasing or no power to twinned unit. Check twinning wiring. Confirm that both twinned units have power.

Documented for: TM9T, TM8T, TMLT

Likely causes, most common first

  1. Incorrect 24V phasing between twinned furnaces
  2. No power to the twinned unit
  3. Twinning wiring error

What you can safely check yourself

  • Check the breaker and service switch for the second (twinned) furnace are on

When to call a technician

Have a technician verify the twinning wiring and 24V transformer phasing between the two furnaces.

A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.