A Carrier furnace LED pattern starting with 4 flashes matches 8 documented codes: 41, 42, 43, 45, 45.1, 45.2, 45.3, 46.1. Watch the full pattern (short vs. long flashes) to tell them apart — all 8 are explained below.

Code 41: Blower motor fault

WarningShown as: 4 short flashes, 1 long flash

Blower motor fault. The blower failed to reach 250 RPM, or failed to report back to the control within the allowed time (30 seconds after start, or 10 seconds during steady operation).

Manual wording: “41 BLOWER MOTOR FAULT - Indicates the blower failed to reach 250 RPM or the blower failed to communicate within the prescribed time limits.

Documented for: 58MVP, 58UVB and other variable-speed two-stage Carrier furnaces

Likely causes, most common first

  1. Failed blower motor or motor module
  2. Loose blower motor wiring or communication connection
  3. Blower wheel jammed or seized

What you can safely check yourself

  • Make sure the blower access door is fully closed and latched
  • Turn the furnace off at the service switch for a minute, then back on once, to force a fresh start

When to call a technician

Testing an ECM/variable-speed blower motor and its module requires a technician. Repeating this code usually means the motor or module is failing.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Full page for Carrier code 41

Code 42: Inducer motor fault

WarningShown as: 4 short flashes, 2 long flashes

Inducer motor fault. The inducer did not start within 20 seconds of a call for heat, its RPM is outside the valid range, or the RPM signal was lost for 5 seconds during operation.

Manual wording: “42 INDUCER MOTOR FAULT - Indicates the inducer has not started within 20 seconds after a call for heat, the inducer motor RPM is outside its valid range of operation, or the inducer RPM signal was lost for 5 seconds during operation.

Documented for: 58MVP, 58UVB and other variable-speed two-stage Carrier furnaces

Likely causes, most common first

  1. Improper vent sizing
  2. Restricted combustion air supply
  3. Failed inducer motor
  4. Improper motor wiring

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice, or debris blocking them

When to call a technician

The inducer motor and its wiring have to be tested by a technician. A furnace that cannot run its inducer cannot vent combustion gases safely.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Full page for Carrier code 42

Code 43: The low-heat pressure switch is open while the high-heat pressure switch is closed - a contradictory pressure switch state on a two-stage furnace

WarningShown as: 4 short flashes, 3 long flashes

The low-heat pressure switch is open while the high-heat pressure switch is closed - a contradictory pressure switch state on a two-stage furnace.

Manual wording: “43 LOW-HEAT PRESSURE SWITCH OPEN WHILE HIGH-HEAT PRESSURE SWITCH IS CLOSED

Documented for: 58MVP, 58UVB and other variable-speed two-stage Carrier furnaces

Likely causes, most common first

  1. Low inlet gas pressure (if a low gas pressure switch is used)
  2. Plugged condensate drain
  3. Improper pressure switch wiring
  4. Water in the vent piping from a sagging pipe
  5. Stuck-open low-heat pressure switch
  6. Disconnected or obstructed pressure tubing

What you can safely check yourself

  • Check the condensate drain line and trap for a clog or standing water
  • Check the outdoor vent terminations for blockage

When to call a technician

Pressure switch wiring and vent piping slope are technician diagnostics. Never jumper a pressure switch.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Full page for Carrier code 43

Code 45: Control circuitry lockout

Soft lockoutShown as: 4 short flashes, 5 long flashes

Control circuitry lockout. The board detected an internal failure and locks out, auto-resetting after 1 hour.

Manual wording: “45 CONTROL CIRCUITRY LOCKOUT - Auto-reset after 1 hour lockout due to: - Flame sense circuit failure. - Gas valve relay stuck open. - Software check error.

Documented for: 58SC0A, 58MCB, 58MVP, 58UVB

Likely causes, most common first

  1. Flame sense circuit failure
  2. Gas valve relay stuck open
  3. Software check error

What you can safely check yourself

  • Turn the furnace off at the service switch for a minute and back on once - the manual says resetting power clears this lockout

When to call a technician

If code 45 comes back after a power reset, the manual's own instruction is to replace the control board - that is a technician job.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Full page for Carrier code 45

Code 45.1: Control failure - flame circuit fault, memory mismatch, or sequence error inside the control board

Soft lockoutShown as: Major code 45 on the LED (4 short, 5 long); 45.1 on the 3-digit display

Control failure - flame circuit fault, memory mismatch, or sequence error inside the control board.

Manual wording: “45.1 CONTROL FAILURE - flame circuit fault, memory mismatch or sequence error.

Documented for: 58SC0B/58SC1B

Likely causes, most common first

  1. Internal control board failure

What you can safely check yourself

  • Turn the furnace off at the service switch for a minute and back on once - the manual says to cycle power

When to call a technician

The manual says that if code 45 repeats after a power cycle, replace the control. That is a technician job.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Full page for Carrier code 45.1

Code 45.2: Control failure - the gas valve relay on the control board will not close

Safety faultShown as: Major code 45 on the LED (4 short, 5 long); 45.2 on the 3-digit display

Control failure - the gas valve relay on the control board will not close.

Manual wording: “45.2 CONTROL FAILURE - gas valve relay will not close.

Documented for: 58SC0B/58SC1B

Likely causes, most common first

  1. Failed gas valve relay on the control board

What you can safely check yourself

  • Turn the furnace off at the service switch and leave it off until a technician arrives

When to call a technician

A gas valve relay that will not close means the board can no longer control gas flow reliably. Shut the furnace off and call a technician; the manual's fix is to replace the control.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Full page for Carrier code 45.2

Code 45.3: Control failure - EEPROM memory issue on the control board

Soft lockoutShown as: Major code 45 on the LED (4 short, 5 long); 45.3 on the 3-digit display

Control failure - EEPROM memory issue on the control board.

Manual wording: “45.3 CONTROL FAILURE - EEPROM memory issue.

Documented for: 58SC0B/58SC1B

Likely causes, most common first

  1. Corrupted or failed memory on the control board

What you can safely check yourself

  • Turn the furnace off at the service switch for a minute and back on once

When to call a technician

If the code repeats after cycling power, the manual says to replace the control board.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Full page for Carrier code 45.3

Code 46.1: Momentary loss of power

StatusShown as: Major code 46 on the LED (4 short, 6 long); 46.1 on the 3-digit display

Momentary loss of power. Heating stops and restarts on its own once the power fluctuation is resolved.

Manual wording: “46.1 MOMENTARY LOSS of power - Heating operation will stop and will restart once the power fluctuation is resolved.

Documented for: 58SC0B/58SC1B

Likely causes, most common first

  1. Brownout or brief power interruption to the furnace

What you can safely check yourself

  • Nothing to fix if you had a power blip
  • If it happens often, check that the breaker is fully seated and the furnace service switch is not loose

When to call a technician

Frequent 46.1 codes with no utility outages point to a loose 115 V connection or failing door switch - have a technician check it.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Full page for Carrier code 46.1