HVAC Code Lookup

Carrier Furnace Code 45

Soft lockoutShown as: 4 short flashes, 5 long flashes

Control circuitry lockout. The board detected an internal failure and locks out, auto-resetting after 1 hour.

Manual wording: “45 CONTROL CIRCUITRY LOCKOUT - Auto-reset after 1 hour lockout due to: - Flame sense circuit failure. - Gas valve relay stuck open. - Software check error.

Documented for: 58SC0A, 58MCB, 58MVP, 58UVB

Likely causes, most common first

  1. Flame sense circuit failure
  2. Gas valve relay stuck open
  3. Software check error

What you can safely check yourself

  • Turn the furnace off at the service switch for a minute and back on once - the manual says resetting power clears this lockout

When to call a technician

If code 45 comes back after a power reset, the manual's own instruction is to replace the control board - that is a technician job.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.