HVAC Code Lookup

Trane Furnace Code E4.0

Soft lockout

The high limit switch has opened because the furnace overheated. This is the newer control's more specific version of E04.

Manual wording: “Open high limit switch

Documented for: S8V2 two-stage induced draft furnaces (FNR-SVX003A control revision)

Likely causes, most common first

  1. Open high limit switch
  2. Restricted airflow from a dirty filter or blocked returns
  3. Blower not running or running slow

What you can safely check yourself

  • Check the air filter and clean or replace it if dirty
  • Check that supply registers and return grilles are open and unblocked
  • Make sure nothing is blocking the return air path to the furnace

When to call a technician

If the limit keeps opening with a clean filter and open vents, a technician needs to find why the furnace is overheating. Do not bypass the limit.

A Trane furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.