Trane Furnace Code E3.4
Soft lockout
The second-stage pressure switch will not close, so the furnace cannot go to high fire.
Manual wording: “Open Pressure Switch, 2nd Stage”
Documented for: Two-stage S8V2, S9V2 and S9V2-VS furnaces
Likely causes, most common first
- Open pressure switch, 2nd stage
- Restricted or blocked venting
- Draft inducer not reaching high-stage speed
- Pressure switch tubing problem
What you can safely check yourself
- Check the outdoor intake and exhaust terminations for blockage
- Check the condensate drain and trap for a clog (condensing models)
When to call a technician
If the venting is clear, the second-stage pressure switch or inducer needs a technician.
A Trane furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.