Trane Furnace Code E3.1
Soft lockout
The first-stage pressure switch is reading closed when the control expects it to be open, which the control calls a shorted pressure switch.
Manual wording: “Shorted Pressure Switch, 1st Stage”
Documented for: S8V2, S9V2 and S9V2-VS furnaces; on single-stage S8B1 the same code reads simply 'Shorted Pressure Switch'
Likely causes, most common first
- Shorted pressure switch, 1st stage
- Pressure switch contacts stuck closed
- Wiring fault across the pressure switch
When to call a technician
A stuck pressure switch is a safety-proving device. It must be tested and replaced by a technician, never jumpered.
A Trane furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.