HVAC Code Lookup

Ruud Furnace Code 67

Warning

Mid pressure switch open when it should be closed. Same modulating-only switch as code 65. The furnace keeps heating but firing rates between 50% and 65% are fixed at 70%.

Manual wording: “MID PRESSURE SWITCH OPEN, SHOULD BE CLOSED ... This fault indicates that the mid pressure switch is electrically open when it should be closed.

Documented for: (-)97V modulating furnaces only

Likely causes, most common first

  1. Wind gusts
  2. Improper venting
  3. Bad wiring to mid pressure switch
  4. Bad mid pressure switch
  5. Bad furnace control

What you can safely check yourself

  • Check the outdoor intake and exhaust terminations for snow, ice or debris.
  • The manual notes wind gusts can trip it - if it clears when the wind drops, mention that to your technician.

When to call a technician

Vent length and construction, pressure switch and control replacement are technician work.

A Ruud furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Ruud codes