Ruud Furnace Code 65

Warning

Mid pressure switch closed when it should be open. Modulating furnaces use a third (mid) pressure switch to allow the middle firing rates. The furnace still heats, but firing rates between 50% and 65% are forced to 70%.

Manual wording: “MID PRESSURE SWITCH CLOSED, SHOULD BE OPEN ... This fault indicates that the mid pressure switch is electrically closed when it should be open.

Documented for: (-)97V modulating furnaces only

Likely causes, most common first

  1. Bad wiring to mid pressure switch
  2. Bad mid pressure switch
  3. Bad furnace control

What you can safely check yourself

  • Nothing homeowner-serviceable. The furnace will keep heating, just with slightly less firing-rate range.

When to call a technician

A technician needs to check the mid pressure switch wiring and replace the switch or control as needed.

A Ruud furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.