Carrier Furnace Code 31
WarningShown as: 3 short flashes, 1 long flash
Pressure switch did not close, or reopened during the cycle. On single-stage furnaces this is the main vent pressure switch; on two-stage furnaces code 31 is the high-heat pressure switch or relay. If the switch stays open longer than 5 minutes the inducer shuts off for 15 minutes before retrying.
Manual wording: “31 PRESSURE SWITCH DID NOT CLOSE OR REOPENED - If open longer than five minutes, inducer shuts off for 15 minutes before retry.”
Documented for: 58SC0A, 58MCB (single-stage); 58MVP, 58UVB high-heat pressure switch (two-stage)
Likely causes, most common first
- Restricted vent, or the intake/exhaust pipe blocked by snow, ice, leaves or a nest
- Plugged condensate drain
- Excessive wind at the vent termination
- Disconnected or obstructed pressure tubing
- Defective inducer motor or low inducer voltage
- Defective or out-of-calibration pressure switch
- Improper vent sizing or inadequate combustion air supply
What you can safely check yourself
- Go outside and check the furnace intake and exhaust pipes for snow, ice, leaves, or a bird/insect nest, and clear anything blocking them
- Check the condensate drain line and trap for a clog or standing water
- Check that the air filter is clean
When to call a technician
If the vent pipes are clear and the drain is not clogged, the inducer motor, pressure switch, or tubing needs a technician. Never jumper a pressure switch to make the furnace run.
A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.