Safety faultShown as: Major code 14 flashed on the LED (1 short, 4 long); 14.3 on the 3-digit display

Flame lost lockout. The flame signal was lost seven times during a single heat request.

Manual wording: “14.3 FLAME LOST LOCKOUT - Flame signal was lost 7 times during a single heat request. See status code 34.2 to 34.3.

Documented for: 58SC0B/58SC1B

Likely causes, most common first

  1. Incorrect manifold pressure and gas firing rate
  2. Gas inlet pressure fluctuations
  3. Flame sensing problem - see codes 34.2 and 34.3

What you can safely check yourself

  • Check that the furnace filter is clean and supply and return vents are open

When to call a technician

Repeated flame loss inside one heat call needs a technician to check gas pressure and the combustion setup. Do not keep resetting the furnace to force it to run.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source